EVFTFT618

EVFTFT618

Controller for retarding-proofing cabinets and rooms, with colour TFT graphic display, in split version
EVFTFT618 is a controller with elegant design for the management of retarding-proofing cabinets and rooms.
Available in split version, the user interface consists of a colour TFT graphic display, touch keys and IP65 protection for easy cleaning.
It is able to manage automatic retarding-proofing cycles (stopping, storing, awakening, proofing and slowing phases), manual storing and proofing cycles (with independent temperature, humidity and ventilation intensity management for each phase).
It also has the “programs” function (to store the settings of the automatic retarding-proofing cycles in a program to be selected and run later on) and a USB communication port (to allow the upload and the download of the settings and the data recorded by the controller, through a common USB flash drive).
The user interface installed from behind using threaded studs enables it to be placed flush with the panel thus making it fit perfectly with the design of the unit.
Technical sheet
Generate PDF

Advantages & Main Features

Elegant design, touch-keys, flush mounting and ease of use.
Aesthetic fit with the unit.
USB communication port for common USB flash drive.
IP65 protection.
Management of automatic retarding-proofing cycles, manual storing and proofing cycles (with independent temperature, humidity and ventilation intensity management for each phase).
Dehumidification management through dehumidifier or compressor activation.
Pump down valve management, timed or through low pressure switch.
“Programs” function (to store the settings of the automatic retarding-proofing cycles in a program to be selected and run later on).

Technical Features

Controller for retarding-proofing cabinets and rooms, with colour TFT graphic display, in split version

EVFTFT618N7U
Power supply
230 VAC
Analog inputs
room probe (PTC/NTC)
evaporator probe (PTC/NTC)
condenser probe (PTC/NTC)
humidity probe (4-20 mA)
Digital inputs (for NA/NC contact)
door switch
compressor thermal switch
low pressure switch
high pressure switch
Analog outputs
PWM (evaporator fan)
Digital outputs (electromechanical relays; res. A @ 250 VAC)
compressor16 A
defrost8 A
humidifier8 A
heaters16 A
steam generator8 A
room light8 A
load 4 (default dehumidifier) (1)8 A
load 8 (default pump down valve) (2)8 A
Communication ports
MODBUS RS-485
USB
Other features
real time clock
alarm buzzer
management of automatic retarding-proofing cycles, and of manual storing and proofing cycles
ventilation intensity management
“HACCP” function
“programs” function
  
Notes
(1)configurable for dehumidifier or condenser fan
(2)configurable for pump down valve or evaporator fan.
  
Available options
None.