EVR

EVR

Controllers for small cold rooms, refrigerated display units, ice-cream, pastry and butcher’s shop counters, in compact and split version
EVR is a range of controllers with elegant design for the management of small cold rooms, refrigerated display units, ice-cream, pastry and butcher’s shop counters.
They are available in compact and split version; the user interface consists of a custom display of above average size (with decimal point and function icons), six touch keys and guarantees an IP55 protection rating, for easy cleaning.
The controllers have a 16 res. A in-rush @ 250 VAC or a 30 res. A @ 250 VAC electromechanical relay for the direct control of high power compressors, avoiding the use of contactors.
Some have the real time clock (to store the HACCP alarms), ventilation management in both “on-off” and modulating mode (in this case it is also necessary to use an external speed regulator) and the adaptive defrost management; all have energy saving strategies.
Installation is by panel (from the front), with hooking elastic fins and needs less depth.
Technical sheet
Generate PDF

Advantages & Main Features

Stylish design, touch keys, reduced frontal thickness and less depth.
16 res. A in-rush @ 250 VAC or 30 res. A @ 250 VAC electromechanical relay.
Adaptive defrost management system and energy-saving strategies
Larger than average custom display.
IP55 protection rating.
Models in compact and split version.
MODBUS TTL communication port for EVKEY programming key and for other EVCO products.
Models with real time clock (to store the HACCP alarms).
Models with ventilation management in both “on-off” and modulating mode.

Technical Features

Controllers in compact version

EVR221N7EVR231N7EVR202N7EVR232N7EVR203N7EVR233N9EVR204N7
For
normal temperature units 
low temperature units  
Power supply
115... 230 VAC      
230 VAC 
Analog inputs
room probe (PTC/NTC)
evaporator probe (PTC/NTC)  
condenser probe (PTC/NTC)       (1)
Digital inputs (for NA/NC contact)
door switch/multipurpose
door switch/multipurpose 2       (1)
Digital outputs (electromechanical relays; res. A @ 250 VAC)
compressor16 A in-rush30 A16 A in-rush30 A16 A in-rush30 A16 A in-rush
defrost      8 A
evaporator fan    5 A5 A5 A
load 2 (default defrost) (2)  8 A8 A   
load 2 (default defrost) (3)    8 A8 A 
load 4 (default room light) (4)      8 A
Communication ports
MODBUS TTL, for EVKEY programming key and for other EVCO products
for EVT100 remote indicator      
Other features
low or high relative humidity percentage operation  
condenser overheat alarm system      
adaptive defrost management  
“energy saving” function
“quick cooling” function
  
Notes
(1)configurable for analog input for PTC/NTC probes or for digital input
(2)configurable for room light, demisting heaters, auxiliary, alarm, door heaters, heaters for neutral zone operation, evaporator fan or defrost
(3)configurable for defrost or room light
(4)configurable for room light, demisting heaters, auxiliary, alarm, door heaters, heaters for neutral zone operation or condenser fan.
  
Available options
Alarm buzzer.
EVR234N9
For
normal temperature units 
low temperature units
Power supply
115... 230 VAC
230 VAC 
Analog inputs
room probe (PTC/NTC)
evaporator probe (PTC/NTC)
condenser probe (PTC/NTC) (1)
Digital inputs (for NA/NC contact)
door switch/multipurpose
door switch/multipurpose 2 (1)
Digital outputs (electromechanical relays; res. A @ 250 VAC)
compressor30 A
defrost8 A
evaporator fan5 A
load 2 (default defrost) (2) 
load 2 (default defrost) (3) 
load 4 (default room light) (4)8 A
Communication ports
MODBUS TTL, for EVKEY programming key and for other EVCO products
for EVT100 remote indicator
Other features
low or high relative humidity percentage operation
condenser overheat alarm system
adaptive defrost management
“energy saving” function
“quick cooling” function
  
Notes
(1)configurable for analog input for PTC/NTC probes or for digital input
(2)configurable for room light, demisting heaters, auxiliary, alarm, door heaters, heaters for neutral zone operation, evaporator fan or defrost
(3)configurable for defrost or room light
(4)configurable for room light, demisting heaters, auxiliary, alarm, door heaters, heaters for neutral zone operation or condenser fan.
  
Available options
Alarm buzzer.

Controllers in compact version with compressor protection against mains voltage fluctuations

EVR261N7EVR271N7EVR263N7EVR273N9EVR264N7EVR274N9
For
normal temperature units  
low temperature units  
Power supply
115... 230 VAC    
230 VAC  
Analog inputs
room probe (PTC/NTC)
evaporator probe (PTC/NTC)  
condenser probe (PTC/NTC)     (1) (1)
Digital inputs (for NA/NC contact)
door switch/multipurpose
door switch/multipurpose 2     (1) (1)
Digital outputs (electromechanical relays; res. A @ 250 VAC)
compressor16 A in-rush30 A16 A in-rush30 A16 A in-rush30 A
defrost    8 A8 A
evaporator fan  5 A5 A5 A5 A
load 2 (default defrost) (2)  8 A8 A  
load 4 (default room light) (3)    8 A8 A
Communication ports
MODBUS TTL, for EVKEY programming key and for other EVCO products
for EVT100 remote indicator    
Other features
low or high relative humidity percentage operation  
condenser overheat alarm system    
adaptive defrost management  
“energy saving” function
“quick cooling” function
  
Notes
(1)configurable for analog input for PTC/NTC probes or for digital input
(2)configurable for defrost or room light
(3)configurable for room light, demisting heaters, auxiliary, alarm, door heaters, heaters for neutral zone operation or condenser fan.
  
Available options
Alarm buzzer.

Controllers for low temperature units, in split version

EVRS204N9EVRS235N9EVRS205N9EVRS225N9
Power supply
115... 230 VAC
Analog inputs
room probe (PTC/NTC)  
condenser probe (PTC/NTC) (1)  (1) 
room probe (PTC/NTC/Pt 1000)  
evaporator probe (PTC/NTC)  
evaporator probe (PTC/NTC/Pt 1000)  
auxiliary probe (PTC/NTC/Pt 1000) (2)  (3)  (3)
Digital inputs (for NA/NC contact)
door switch/multipurpose (1) (3) (1) (3)
door switch/multipurpose 2
Analog outputs
PWM (evaporator fan)  
Digital outputs (electromechanical relays; res. A @ 250 VAC)
compressor30 A30 A30 A30 A
defrost16 A16 A16 A16 A
evaporator fan8 A8 A8 A8 A
load 4 (default room light) (4)16 A16 A16 A16 A
load 5 (default alarm) (4) 30 A30 A30 A
Communication ports
MODBUS TTL, for EVKEY programming key and for other EVCO products
Other features
real time clock   
low or high relative humidity percentage operation  
management of the ventilation in both “on-off” and modulating mode  
condenser overheat alarm system
adaptive defrost management
"multideck" function  
“HACCP” function   
“energy saving” function
"quick cooling" function
  
Notes
(1)configurable for analog input for PTC/NTC probes or for digital input
(2)configurable for condenser probe, display probe or CPT probe
(3)configurable for analog input for PTC/NTC/Pt 1000 probes or for digital input
(4)configurable for room light, demisting heaters, auxiliary, alarm, door heaters, heaters for neutral zone operation, condenser fan or compressor 2.
  
Available options
-alarm buzzer
-port for EVT100 remote indicator (not available in models EVRS204 and EVRS205).
Per maggiori informazioni su questa gamma consulta la versione desktop del sito.