Vcolor 338

Vcolor 338

Controller for electric gastronomy and pastry ovens, with 5 or 7-inch colour touch-screen TFT graphic display, in split version
Vcolor 338 is a controller with elegant design for the management of electric gastronomy and pastry ovens (also rotor type).
Available in split version, the user interface consists of a 5-inch (M) or 7-inch (L) capacitive TFT touch-screen graphic display in glass, 65K colours, 800 x 480 pixel resolution and IP65 protection for easy cleaning.
The user interface can be installed recessed from the front or flush with the panel, thus making it fit perfectly with the design of the unit.
It is able to manage the ventilation both in “on-off” and in modulating mode (in this case it is also necessary to use an external speed regulator), with fan reversal.
The controller has full steam management (generation, injection and extraction), in both automatic and manual mode; steam can be generated either directly or through an external boiler module that also manages water charge and discharge, and the "boiler rinsing" and "boiler washing" functions (the steam generation mode can depend on room temperature).
The machine is also capable of washing management, with both liquid detergents and tabs; using an external burners module it is possible to manage gas ovens.
Technical sheet
Generate PDF

Advantages & Main Features

Capacitive TFT touch-screen graphic display, 65K colours, 800 x 480 pixel resolution.
Elegant design, touch-screen, flush mounting and ease of use.
Aesthetic fit with the unit.
Model for different types of electric ovens (including rotary ones).
Management of the ventilation in both “on-off” and modulating mode, with fan reversal.
Full steam management (generation, injection and extraction), both in automatic and manual mode.
Steam generation in direct mode or through the use of an external boiler module.
Washing management with both liquid detergent and tab.
Management of gas ovens using an external burners module.

Technical Features

Controllers with 5-inch graphic display

Vcolor 338M
(5")
BoilerBurners
EVCMC33DJ2EEVCMC33DC2EEVCLE305XXEEVCLE302XXE
Power supply
12 VAC  
fed by the controller  
Digital inputs (for NA/NC contact)
boiler motor protection (230 VAC)   
presence of a pilot light (230 VAC)   
presence of boiler flame (230 VAC)   
door switch  
rack limit switch  
fan thermal switch (230 VAC)  
thermal switch (230 VAC)  
electrical absorption (230 VAC)  
boiler water minimum level  
boiler water maximum level  
Digital outputs (electromechanical relays; res. A @ 250 VAC)
boiler temperature regulation  1 A 
boiler steam injection  1 A 
boiler water drain  1 A 
boiler water charge  1 A 
boiler burner   1 A
room burner   1 A
temperature regulation1 A1 A  
direct steam injection1 A1 A  
air vent1 A1 A  
room light1 A1 A  
electronics compartment fan1 A1 A  
rack rotation1 A1 A  
load 7 (default fan)1 A1 A  
load 8 (default not used)1 A1 A  
load 9 (default fume reduction)1 A1 A  
load 10 ( default washing water valve)1 A1 A  
load 11 (liquid detergent injection default)1 A1 A  
load 12 (default washing liquid discharge)1 A1 A  
load 13 (default rinse aid injection)1 A1 A  
Analog inputs
chamber probe (J/K)   
chamber probe (2 wires Pt 100)   
fume probe (J/K)   
boiler probe (Pt 100 2 wires)   
needle probe (J/K)   
needle probe (2 wires Pt 100)   
fume probe (2 wires Pt 100)   
boiler probe (J/K)   
Communication ports
MODBUS RS-485  
USB  
for electronic ignition card for atmospheric burners   
Analog outputs
0-10 V (fan)  
Other features
real time clock  
alarm buzzer  
management of the ventilation both in “on-off” and in modulating mode, with fan reversal  
washing management with both liquid detergent and tab  
“Weekly programmed switch on” function  
“programs” function  
  
Notes
None.
  
Available options
For other models please contact the EVCO sales network.

Controllers with 7-inch graphic display

Vcolor 338L
(7")
BoilerBurners
EVCLC33DC2EVCLE305XXEEVCLE302XXEEVCLC33DJ2
Digital outputs (electromechanical relays; res. A @ 250 VAC)
boiler temperature regulation 1 A  
boiler steam injection 1 A  
boiler water drain 1 A  
temperature regulation1 A  1 A
direct steam injection1 A  1 A
air vent1 A  1 A
room light1 A  1 A
electronics compartment fan1 A  1 A
rack rotation1 A  1 A
load 7 (default fan)1 A  1 A
load 8 (default not used)1 A  1 A
load 9 (default fume reduction)1 A  1 A
load 10 ( default washing water valve)1 A  1 A
load 11 (liquid detergent injection default)1 A  1 A
load 12 (default washing liquid discharge)1 A  1 A
load 13 (default rinse aid injection)1 A  1 A
boiler water charge 1 A  
boiler burner  1 A 
room burner  1 A 
Analog inputs
chamber probe (J/K)   
chamber probe (2 wires Pt 100)   
needle probe (J/K)   
needle probe (2 wires Pt 100)   
fume probe (J/K)   
fume probe (2 wires Pt 100)   
boiler probe (J/K)   
boiler probe (Pt 100 2 wires)   
Power supply
12 VAC  
fed by the controller  
Digital inputs (for NA/NC contact)
door switch  
rack limit switch  
fan thermal switch (230 VAC)  
thermal switch (230 VAC)  
electrical absorption (230 VAC)  
boiler water minimum level  
boiler water maximum level  
boiler motor protection (230 VAC)   
presence of a pilot light (230 VAC)   
presence of boiler flame (230 VAC)   
Analog outputs
0-10 V (fan)  
Communication ports
MODBUS RS-485  
USB  
for electronic ignition card for atmospheric burners   
Other features
real time clock  
alarm buzzer  
management of the ventilation both in “on-off” and in modulating mode, with fan reversal  
washing management with both liquid detergent and tab  
“Weekly programmed switch on” function  
“programs” function  
  
Notes
None.
  
Available options
For other models please contact the EVCO sales network.
Per maggiori informazioni su questa gamma consulta la versione desktop del sito.