EV3B7/EV3B8

EV3B7/EV3B8

Controllers for refrigeration with compressor protection against mains voltage fluctuations
EV3B7/EV3B8 controllers are able to protect the compressor against mains voltage fluctuations, preventing it from being switched on (or causing it to switch off) if voltage is outside an allowed range, while ensuring the cooling of the cabinet (patented function).
Some controllers have a 30 res. A @ 250 VAC electromechanical relay for the direct control of high power compressors, avoiding the use of contactors; all have adaptive management of the defrost function and can implement energy-saving strategies.
They are available in compact and standard 74 x 32 mm format. The user interface consists of a larger than average custom display, with decimal point and function icons, and four touch keys. It guarantees IP65 protection for easy cleaning.
Installation is by panel, with snap-in brackets.
Technical sheet
Generate PDF

Advantages & Main Features

Compressor with mains voltage fluctuation protection
Models with 30 res. A @ 250 VAC electromechanical relay.
Compliant with the standard EN 60079-15 for use on equipment using hydrocarbons (R290).
Cooling/heating operation.
Adaptive defrost management and energy saving strategies.
Standard size 74 x 32 mm.
Capacitive touch keys.
IP65 protection.

Technical Features

Controllers in compact version with compressor protection against mains voltage fluctuations

EV3B71N9EV3B81N9EV3B73N9EV3B83N9
For
normal temperature units  
low temperature units  
Power supply
115... 230 VAC
Analog inputs
cabinet probe (PTC/NTC)
auxiliary probe (PTC/NTC)  
Digital inputs (for NA/NC contact)
door switch/multipurpose  
Configurable inputs
analogue input (PTC/NTC) or digital input (multi-purpose)  
Digital outputs (electromechanical relays; res. A @ 250 VAC)
compressor16 A30 A16 A30 A
configurable (default cabinet light)  8 A8 A
configurable (default evaporator fan)  5 A5 A
Other features
operation with EV3KEY
cooling/heating operation
condenser overheat alarm system
adaptive defrost management
"energy saving" function
  
Notes
None.
  
Available options
With full-sealed relays for equipment using hydrocarbons.