EVBOX1

EVBOX1

Control panels for single-phase cold rooms
EVBOX1 is a range of electrical controllers for the management of single-phase cold rooms.
The user interface consists of a large custom display with decimal point and function icons, with six buttons. It guarantees IP65 frontal protection.
The controllers use two relays, rated load 30 res. A @ 250 VAC, for direct control of high-power compressors and of the evaporator fan, thus avoiding the use of contactors.
They can be adjusted for low and high relative humidity and feature an adaptive defrost system and energy-saving strategies.
Some models have a thermal-magnetic circuit breaker, a clock for memorising HACCP alarms and include a driver for unipolar stepper-type electronic expansion valves.
The controllers are designed to be wall-mounted, with fixing screws and plugs.
Technical sheet
Generate PDF

Advantages & Main Features

Models with a driver for unipolar stepper-type electronic expansion valves.
Variety of models for different typologies of cold rooms.
30 res. A @ 250 VAC electromechanical relay.
Adaptive defrost management and energy saving strategies.
Models with thermal magnetic circuit breaker.
On/stand-by key.
Big size custom display.
IP65 protection.
MODBUS RS-485 communication port.

Technical Features

Electrical controllers with separate power supply for the loads

EVB1204N9EVB1206N9EVB1206N9MEVB1216N9EVB1216N9MEVB1246N9MEVB1256N9M
Power supply
115... 230 VAC
Analog inputs
room probe (PTC/NTC/Pt 1000)
evaporator probe (PTC/NTC/Pt 1000)
auxiliary probe (PTC/NTC/Pt 1000)
suction pressure probe (4-20 mA)     
evaporating temperature probe (PTC/NTC/Pt 1000)     
Digital inputs (for NA/NC contact)
door switch
multipurpose
multipurpose 2
Digital outputs (electromechanical relays; res. A @ 250 VAC)
compressor30 A30 A30 A30 A30 A30 A30 A
defrost16 A16 A16 A16 A16 A16 A16 A
evaporator fan30 A30 A30 A30 A30 A30 A30 A
room light 16 A16 A16 A16 A16 A16 A
load 4 (default room light)8 A      
load 5 (default condenser fan) 8 A8 A8 A8 A8 A8 A
load 6 (default alarm) 8 A8 A8 A8 A8 A8 A
Communication ports
MODBUS RS-485
Connectivity
RS-485 MODBUS RTU (built-in)
Other features
real time clock    
alarm buzzer
unipolar thermal magnetic circuit breaker + neutral (230 VAC, In 16 A, Icn 4.500 A)   
integrated unipolar stepper electronic expansion valves driver     
low or high relative humidity percentage operation
condenser overheat alarm system
adaptive defrost management
"multideck" function
“HACCP” function   
“energy saving” function
“quick cooling” function
  
Notes
None.
  
Available options
None.

Electrical controllers with direct connection of loads

EVB1204N9XXCEVB1206N9XXCEVB1206N9MXC
Power supply
115... 230 VAC
Analog inputs
room probe (PTC/NTC/Pt 1000)
evaporator probe (PTC/NTC/Pt 1000)
auxiliary probe (PTC/NTC/Pt 1000)
Digital inputs (for NA/NC contact)
door switch
multipurpose
multipurpose 2
Digital outputs (electromechanical relays; res. A @ 250 VAC)
compressor30 A30 A30 A
defrost16 A16 A16 A
evaporator fan30 A30 A30 A
room light 16 A16 A
load 4 (default room light)8 A  
load 5 (default condenser fan) 8 A8 A
load 6 (default alarm) 8 A8 A
Communication ports
MODBUS RS-485
Connectivity
RS-485 MODBUS RTU (built-in)
Other features
alarm buzzer
unipolar thermal magnetic circuit breaker + neutral (230 VAC, In 16 A, Icn 4.500 A)  
low or high relative humidity percentage operation
condenser overheat alarm system
adaptive defrost management
"multideck" function
"energy saving" function
“quick cooling” function
  
Notes
None.
  
Available options
None.