EVBOX1 Datalogging

EVBOX1 Datalogging

Electrical control panels for single-phase cold rooms
EVBOX1 Datalogging is a range of electrical control panels for single-phase cold rooms with data-logging extension for compliance with the EN12830 standard
Equipped with up to 6 relay outputs, the electrical panels can regulate with great flexibility and energy savings the most varied equipment configurations on the market, including those with management of temperatures as low as -99°C.
The controllers use two relays, rated load 30 A @ 250 VAC, for direct control of high-power compressors and the evaporator fan and they can be adjusted for low and high relative humidity.
Some models have a thermal-magnetic circuit breaker. They all have a clock for memorising HACCP alarms and a data-logging extension on an SD card with built-in battery for data recording, even in the event of a power failure.
The user interface consists of a large custom display with decimal point and function icons, with six buttons. It guarantees IP65 frontal protection. The controllers are designed to be wall-mounted, with fixing screws and plugs.
Technical sheet
Generate PDF

Advantages & Main Features

Data-logging extension on SD card for compliance with the EN12830 standard.
Variety of models for different typologies of cold rooms.
30 res. A @ 250 VAC electromechanical relay.
Models with thermal magnetic circuit breaker.
MODBUS RS-485 communication port.
Adaptive defrost management and energy saving strategies.
Real time clock.
Big size display.
IP65 protection.

Technical Features

Electrical control panels for single-phase cold rooms

EVB1214N9XLCEVB1216N9XLCEVB1216N9MLC
Power supply
115... 230 VAC
Analog inputs
room probe (PTC/NTC/Pt 1000)
evaporator probe (PTC/NTC/Pt 1000)
auxiliary probe (PTC/NTC/Pt 1000)
auxiliary probe 2 (NTC/Pt 1000)
auxiliary probe 3 (NTC/Pt 1000)
Digital inputs (for NA/NC contact)
door switch
multipurpose
multipurpose 2
Digital outputs (electromechanical relays; res. A @ 250 VAC)
load 4 (default room light)8 A  
load 5 (default condenser fan) 8 A8 A
load 6 (default alarm) 8 A8 A
compressor30 A30 A30 A
defrost16 A16 A16 A
evaporator fan30 A30 A30 A
room light 16 A16 A
Communication ports
MODBUS RS-485
Connectivity
RS-485 MODBUS RTU (built-in)
Other features
real time clock
alarm buzzer
“energy saving” function
“quick cooling” function
unipolar thermal magnetic circuit breaker + neutral (230 VAC, In 16 A, Icn 4.500 A)  
data-logging extension on SD card for compliance with the EN12830 standard
low or high relative humidity percentage operation
condenser overheat alarm system
adaptive defrost management
"multideck" function
“HACCP” function
  