| Vcolor 388 M L with J/K thermocouples | Vcolor 388 M L with 2 wires Pt 100 | Optional expansion modules with 2 relays (max. 2) |
| EVCMC38FJ2E | EVCLC38FJ2E | EVCMC38FC2E | EVCLC38FC2E | EVCLE322XXE n. 1 | EVCLE322XXE n. 2 |
| AFFICHEUR |
| 5" capacitive TFT touch-screen colour graphic display | • | | • | | | |
| 7" capacitive TFT touch-screen colour graphic display | | • | | • | | |
| ALIMENTATION |
| Module de contrôle | 12 VAC | 12 VAC | 12 VAC | 12 VAC | | |
| Interface utilisateur alimentée par le module de contrôle | • | • | • | • | | |
| Expansion module (powered by the control module) | | | | | • | • |
| ENTRÉES ANALOGIQUES |
| Sonde chambre | • | • | • | • | | |
| INGRESSI DIGITALI PER CONTATTO NA/NC (a contatto pulito) |
| Safety thermostat for combustion and cooking chamber fumes (connected in series) | • | • | • | • | | |
| Chimney adjustment rod | • | • | • | • | | |
| Motorised chimney damper | • | • | • | • | | |
| Burner door | • | • | • | • | | |
| INGRESSI DIGITALI PER CONTATTO NA/NC (in alta tensione 230 VAC) |
| Burner block | • | • | • | • | | |
| Fan block | • | • | • | • | | |
| SORTIES NUMÉRIQUES (relais électromécaniques ; A rés. à 250 VAC) |
| Configurable (default burner) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default burner block) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default combustion fume extraction) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default steam injection deck 5) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default chamber light) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default suction hood) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default electronics compartment fan) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default sound) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default burner power supply) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default steam injection deck 1) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default steam injection deck 2) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default steam injection deck 3) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default steam injection deck 4) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default fan motor) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default venting deck 1) | 5 A | 5 A | 5 A | 5 A | | |
| Configurable (default venting deck 2) | | | | | 5 A | |
| Configurable (default venting deck 3) | | | | | 5 A | |
| Configurable (default venting deck 4) | | | | | | 5 A |
| Configurable (default venting deck 5) | | | | | | 5 A |
| PORT DE COMMUNICATION |
| RS-485 MODBUS | • | • | • | • | | |
| USB | • | • | • | • | | |
| CONNECTIVITY |
| RS-485 MODBUS RTU (built-in) | • | • | • | • | | |
| Wi-Fi EPoCA/MODBUS TCP (optional through the EVlinking Wi-Fi module powered by controller) | • | • | • | • | | |
| Ethernet EPoCA/MODBUS TCP (optional through the EVCO gateways EV3 Web or EVD Web) | • | • | • | • | | |
| AUTRES CARACTÉRISTIQUES D'ORIGINE |
| Horloge | • | • | • | • | | |
| Buzzer d'alarme | • | • | • | • | | |
| |
| Notes |
| Aucune. |
| |
| Options disponibles |
| Aucune. |