| EVYB13LN9 | EVYB14LN9 | EVYB15LN9 | EVYB33LN9 | EVYB34LN9 | EVYB35LN9 | EVYB35LN9VFT |
VISUALIZADOR |
LED display, 3+3 capacitive keys | • | • | • | • | • | • | • |
CONEXIONES |
Terminales de conexiones de tornillo fijos | • | • | • | • | • | • | • |
ALIMENTACIÓN |
115... 230 VAC | • | • | • | • | • | • | • |
ENTRADAS ANALÓGICAS (configurables) |
Default cabinet probe (PTC/NTC/Pt 1000) | • | • | • | • | • | • | • |
Default evaporator probe (PTC/NTC/Pt 1000) | • | • | • | • | • | • | • |
Default condenser probe (PTC/NTC/Pt 1000) | • | • | • | • | • | • | • |
INGRESSI DIGITALI (a contatto pulito) |
Micro-interruptor puerta | • | • | • | • | • | • | • |
Multifunción | • | • | • | • | • | • | • |
DIGITAL OUTPUTS (full-sealed relays; A res. @ 250 VAC) |
Configurable (default compresor) | 16 A | 16 A | 16 A | 30 A | 30 A | 30 A | 30 A |
Configurable (default ventiladores evaporador) | 8 A | 8 A | 8 A | 8 A | 8 A | 8 A | 8 A |
Configurable (default alarma) | 8 A | 8 A | 8 A | 8 A | 8 A | 8 A | 8 A |
Configurable (default luz cámara) | | 8 A | 8 A | | 8 A | 8 A | 8 A |
Configurable (default desescarche) | | | 8 A | | | 8 A | 8 A |
ALTRE USCITE |
Configurable for PWM (variable speed compressors) or 0-10 V (variable speed compressors or modulating fans) | • | • | • | • | • | • | • |
PUERTOS DE COMUNICACIÓN |
TTL MODBUS | • | • | • | • | • | • | • |
Para display remoto | | | | | | | • |
CONNECTIVITY |
Bluetooth Low Energy for EVconnect app (optional through the EVlinking BLE module) | • | • | • | • | • | • | • |
Wi-Fi EPoCA/MODBUS TCP (optional through the EVlinking Wi-Fi module powered by controller) | • | • | • | • | • | • | • |
Ethernet EPoCA/MODBUS TCP (optional through the EVCO gateways EV3 Web or EVD Web) | • | • | • | • | • | • | • |
OTRAS CARACTERÍSTICAS |
Sirena de alarma | • | • | • | • | • | • | • |
|
Notas |
Ninguna. |
|
Opciones disponibles |
|
| EVY216LN9 | EVY236LN9 | EVY236LN9XFT |
VISUALIZADOR |
LED display, 3+3 backlit capacitive keys | • | • | • |
CONEXIONES |
Plug-in screw terminal blocks (to be ordered separately) | • | • | • |
ALIMENTACIÓN |
115... 230 VAC | • | • | • |
ENTRADAS ANALÓGICAS (configurables) |
Default cabinet probe (PTC/NTC/Pt 1000) | • | • | • |
Default evaporator probe (PTC/NTC/Pt 1000) | • | • | • |
Default condenser probe (PTC/NTC/Pt 1000) | • | • | • |
INGRESSI DIGITALI (a contatto pulito) |
Micro-interruptor puerta | • | • | • |
Multifunción 1 | • | • | • |
Multifunción 2 | • | • | • |
ENTRADAS CONFIGURABLES (ANALÓGICAS O DIGITALES) |
Entrada analógica (PTC/NTC/Pt 1000) o entrada digital (contacto seco) | • | • | • |
DIGITAL OUTPUTS (full-sealed relays; A res. @ 250 VAC) |
Configurable (default compresor) | 16 A | 30 A | 30 A |
Configurable (default ventiladores evaporador) | 8 A | 8 A | 8 A |
Configurable (default alarma) | 8 A | 8 A | 8 A |
Configurable (default luz cámara) | 8 A | 8 A | 8 A |
Configurable (default desescarche) | 8 A | 8 A | 8 A |
Configurable (default on/stand-by) | 16 A | 16 A | 16 A |
ALTRE USCITE |
Configurable for PWM (variable speed compressors) or 0-10 V (variable speed compressors or modulating fans) | 3 | 3 | 3 |
PUERTOS DE COMUNICACIÓN |
TTL MODBUS | • | • | • |
Para display remoto | | | • |
CONNECTIVITY |
Bluetooth Low Energy for EVconnect app (optional through the EVlinking BLE module) | • | • | • |
Wi-Fi EPoCA/MODBUS TCP (optional through the EVlinking Wi-Fi module powered by controller) | • | • | • |
Ethernet EPoCA/MODBUS TCP (optional through the EVCO gateways EV3 Web or EVD Web) | • | • | • |
OTRAS CARACTERÍSTICAS |
Sirena de alarma | • | • | • |
|
Notas |
Ninguna. |
|
Opciones disponibles |
|
| EVY216DN9 | EVY236DN9 | EVY236DN9PFT | EVY218DN3 | EVY238DN3 | EVY238DN3PFT |
VISUALIZADOR |
2.4" LCD colour graphic display, 4+4 backlit capacitive keys | • | • | | | | |
2.4" LCD colour graphic display, 6+6 backlit capacitive keys | | | | • | • | • |
CONEXIONES |
Plug-in screw terminal blocks (to be ordered separately) | • | • | | • | • | • |
ALIMENTACIÓN |
12... 24 VDC | | | | • | • | • |
ENTRADAS ANALÓGICAS (configurables) |
Default cabinet probe (PTC/NTC/Pt 1000) | • | • | | • | • | • |
Default evaporator probe (PTC/NTC/Pt 1000) | • | • | | • | • | • |
Default condenser probe (PTC/NTC/Pt 1000) | • | • | | • | • | • |
INGRESSI DIGITALI (a contatto pulito) |
Micro-interruptor puerta | • | • | | • | • | • |
Multifunción 1 | • | • | | • | • | • |
Multifunción 2 | • | • | | • | • | • |
Multifunción 3 | • | • | | • | • | • |
ENTRADAS CONFIGURABLES (ANALÓGICAS O DIGITALES) |
Entrada analógica (PTC/NTC/Pt 1000) o entrada digital (contacto seco) | • | • | | • | • | • |
DIGITAL OUTPUTS (full-sealed relays; A res. @ 250 VAC) |
Configurable (default compresor) | 16 A | 30 A | | 16 A | 30 A | 30 A |
Configurable (default ventiladores evaporador) | 8 A | 8 A | | 8 A | 8 A | 8 A |
Configurable (default alarma) | 8 A | 8 A | | 8 A | 8 A | 8 A |
Configurable (default luz cámara) | 8 A | 8 A | | 8 A | 8 A | 8 A |
Configurable (default desescarche) | 8 A | 8 A | | 8 A | 8 A | 8 A |
Configurable (default on/stand-by) | 16 A | 16 A | | 16 A | 16 A | 16 A |
Configurable (default auxiliary load 1) | | | | 16 A | 16 A | 16 A |
Configurable (default auxiliary load 2) | | | | 8 A | 8 A | 8 A |
ALTRE USCITE |
Configurable for PWM (variable speed compressors) or 0-10 V (variable speed compressors or modulating fans) | 3 | 3 | | 3 | 3 | 3 |
12... 24 VDC for control of LED lamps up to 25 W and 50 W | | | | 2 | 2 | 2 |
PUERTOS DE COMUNICACIÓN |
TTL MODBUS | • | • | | • | • | • |
USB-C | • | • | | • | • | • |
Para display remoto | | | | | | • |
CONNECTIVITY |
Bluetooth Low Energy for EVconnect app (optional through the EVlinking BLE module) | • | • | | • | • | • |
Wi-Fi EPoCA/MODBUS TCP (optional through the EVlinking Wi-Fi module powered by controller) | • | • | | • | • | • |
Ethernet EPoCA/MODBUS TCP (optional through the EVCO gateways EV3 Web or EVD Web) | • | • | | • | • | • |
OTRAS CARACTERÍSTICAS |
Sirena de alarma | • | • | | • | • | • |
|
Notas |
Ninguna. |
|
Opciones disponibles |
|